What was found
L HYD ELEC PUMP AND L HYD QTY EIAS AT CRUISE. FOLLOWED BY L HYD SYS PRESS. QRH COMPLETED EMERGENCY DECLARED. PTU OPERATED NORMALLY TO MAINTAIN L SYS PRESSURE ON STATUS PAGE. INSTALLED TEMP FLEX LINE ON LEFT ACMP PRESSURE OUTLET.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L HYD ELEC PUMP AND L HYD QTY EIAS AT CRUISE. FOLLOWED BY L HYD SYS PRESS. QRH COMPLETED EMERGENCY DECLARED. PTU OPERATED NORMALLY TO MAINTAIN L SYS PRESSURE ON STATUS PAGE. INSTALLED TEMP FLEX LINE ON LEFT ACMP PRESSURE OUTLET.