What was found
MAIN CABIN, FWD L/H WET AREA, LBL7 SEAT TRACK CORRODED TAPED AREAS ON SIDE OF TRACK 345 - 379 REMOVED CORROSION, ORIGINAL THICKNESS .072" MATERIAL REMOVED .018", REMAINING .054", OUT OF LIMITS OF B757 SRM 53-10-52-01, FABRICATED SEAT TRACK IAW VENTURA AEROSPACE DWG 3504-NC-2 AND INSTALLED NEW SEAT TRACK IAW VENTURA AEROSPACE DWG 3470 REV G