What was found
CRACK FOUND APPROXIMATE 0.7" IN LENGTH DURING HIGH FREQUENCY EDDY CURRENT INSPECTION ON LEFT HAND SIDE FUSELAGE SKIN AT APPROXIMATELY STATION 1030, STRINGER STRINGER 37L AS MARKED. COMPLIED WITH E.O.# : G-5310-E0332629G P5. TITLE: FUSELAGE - MAINFRAM - INSPECTION AND AND MODIFICATION OF THE UNDERWING LONGERON AT BODY STATION 1035 - BOEING SERVICE SERVICE BULLETINS 777-53A0081 AND 777-53-0087. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.