What was found
HYD 1 OFF LEVEL 1 ALERT 15 MIN INTO CRUISE AT FL380. HYD 1 QTY LO AND HYD 1 PUMP 1R/1L OFF ALERTS CYCLED DURING CONFIGURATION. EMERGENCY DECLARED. SERVICED SYSTEM 1 HYDRAULIC RESERVOIR REF AMM 12-13-02-3. OPERATED NR 1 HYDRAULIC SYSTEM. TRACED LEAK TO LOOSE HYDRAULIC LINE B-NUT ON NR 1 BRAKE SYSTEM UPPER FWD ACCUMULATOR. SECURED THE FITTING IAW AMM 32-44-01-4. SERVICED AND OPERATED THE BRAKES IAW AMM 32-43-20-6. BRAKES OPERATED NORMALLY, WITH NO LEAKS NOTED. AIRCRAFT OK FOR SERVICE.