What was found
DURING REMOVAL OF R1 SLIDE FOUND R1 DOOR EMERGENCY POWER RESERVOIR BOTTLE DISCHARGED. R & R THE EMERGENCY POWER RESERVOIR CYLINDER IAW MM 52-11-30-4, CHECKED OK, .ACFT OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING REMOVAL OF R1 SLIDE FOUND R1 DOOR EMERGENCY POWER RESERVOIR BOTTLE DISCHARGED. R & R THE EMERGENCY POWER RESERVOIR CYLINDER IAW MM 52-11-30-4, CHECKED OK, .ACFT OK FOR SERVICE.