What was found
PDIS 103 05-50 7979 10FEB21 CAN FACT U LOGPAGES:3216454 TWICE ON TAXI-OUT ,ONCE AT BEGINNING OF 20 MIN TAXI OUT AND ONCE AS TAKING RUNWAY BUT BEFORE BEING CLEARED FOR TAKE OFF . VERY STRONG ODOR OF BURNING RUBBER OR PLASTIC NOTED ON FLIGHT DECK. REQUESTING THROUGH INSPECTION OF ALL CARGO COMPARTMENTS TO ENSURE FOR NO SMOKE/FUMES. FACT 10FEB21 22:33 CAN U INSPECTED ALL THE CARGOS AND E/E RACK COMPONENTS ,NO FIRE AND NO SMOKE FOUND ,RAMP UNLOAD ALL THE DG'S AS CREW REQUIRED,INSPECTED L&R ENG INLET AND EXHAUST NO FOD AND NO DAMAGE FOUND PER AMM 72-32-00-6 & 78-11-00-6.PERFORMED PACK SYS TEST WITH APU BLEED AIR PER AMM 21-51-00-5-3 & 21-22-00-0-3 ,ALL TEST NORMAL AND NO ABNORMAL SMELLING.A/C OK FOR SVC.