What was found
FUSELAGE - MAINFRAME - STATION 1640 FUSELAGE FRAME WEB OPEN HOLE HFEC INSPECTION FOUND INBD 2EA HOLES WITH CRACK SIGNAL, AT STGR14RH COMPLIED WITH FEDEX EA: F-5310-T0364784 PT1, EA TITLE: FUSELAGE - MAINFRAME - CRACK INDICATIONS AT RH STA 1640 FUSELAGE FRAME WEB INBOARD HOLES AT S-14R. REPAIRED FUSELAGE - MAINFRAME - STATION 1640 FUSELAGE FRAME WEB INBOARD 2EA CRACKED HOLES, AT STGR14RH. THIS REPAIR IS CATGORY B REPAIR. FOLLOW-UP INSPECTION AND INTERVAL PER FEDEX EA: F-5310-T0364784. MAJOR REPAIR IAW FEDEX GMM6-2-100