What was found
MDIS 110 26-11 8313 16AUG22 MXP OPEN U APU FIRE EXT. BOTTLE DISCHARGE LIGHT ILLUMINATED. MEL 16AUG22 15:22 MXP U RELEASED FOR SERVICE PER MEL : 26-22-01-B CATEGORY : B EXPIRATION : 19AUG22 "MEL 26-22-01-B: APU FIRE EXTINGUISHER - INOP. APU - INOP. REFER TO THE OPERATIONS NOTE FOR DRY ICE REST RICTIONS." THIS FLIGHT MUST REMAIN WITHIN 120 MINUTES OF LANDING AT A SUITABLE AIRPORT. DUE TO A/C DEPARTURE NO TIME FOR T/S. APU EXT SYS INOP, A/C RELEASED I.A.W MEL 26-22-001-B. A/C OK FOR SERVICE. C/7329270 FACT 17AUG22 09:34 CDG REPLACED AND TEST OK APU FIRE EXTINGUISHER BOTTLE/DISCHARGE CARTRIGE PER AMM 26-22-02-04. MEL CLOSED.