What was found
AT THE TIME OF INSPECTION ON EO E1-5100-7-5001 PART 1. MCD RIGHT HAND STATION 1641 BETWWEEN LONGERON 12 TO 13 FOUND A DENT ON THE FUSELAGE FRAME THAT WAS NOT DOCUMENTED FOR EVALUATIONS. MAIN DECK CARGO COMPARTMENT RIGHT HAND STATION 1641 BETWEEN LONGERON 12 TO 13 ON THE FUSELAGE FRAME DENTED AREA REPAIRED AS PER SRM 53-00-07-2R FIGURE 201 REPAIR 2. INITIAL INSPECTION TO BE CARRY OUT AT 14,500 FLIGHT CIRCLES AND REPETITIVE INSPECTION AT EVERY 9,500 FLIGHT CIRCLES. INSPECTION METHOD HIGH FREQUENCY EDDY CURRENT AS PER SRM 53-00-07-2R FIGURE 201 REPAIR 2 TABLE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.