EMERGENCY DECLARED: RECEIVED GREEN HYD LOW LVL. COMPLIED WITH ECAM AND QRH DECLARED EMERGENCY AND PERFORMED LANDING GEAR GRAVITY EXTEND. 1. PER AMM 29-21-00-03 PRESSURED THE GREEN HYD SYS AND CHECK THE LEAKAGE. RESULT: LEAKAGE FOUND AT THREE POSITIONS. (1)ELBOW OF GREEN HTD SYS HP MAINFOLD. (2)HYDRAULIC LINE OF AUTOMATIC SELECTOR. (3)RH LDG DOOR UPLOCK ASSY. 2. RECORDED THE GREEN SYS HYD QUANTITY RESULT: 5 GALLONS 3. PER AMM 29-11-12-04 & AMM 20-23-12-00 REPLACED THE PACKING AND BACKUP PACKING OF THE ELBOW OF GREEN HYD SYS HP MANIFOLD 4. PER AMM 29-00-00-03 CHECKED CLOGGING INDICATORS OF GREEN HYD SYS, CHECKED NORMAL 5. PER AMM 12-12-29-00 REPLENISHED THE GREEN HYD SYS 6. PER AMM 71-00-00-05 PERFORMED ENG IDLE TEST AND PRESSURE THE GREEN HYD SYS WITH EDPS THEN CHECK THE LEAKAGE, RECORD THE RESULT NO LEAKAGE 7. PER AMM 32-42-13-04 & AMM 20-23-12-00 REPLACED THE HYDRAULIC LINE OF AUTOMATIC SELECTOR (1300) 8. PER AMM 32-31-33-04 & AMM 20-23-12-00 REPLACED THE PACKING OF RH LDG DOOR UPLOCK ASSY 9. PER ASM 29-31-00 & AWM 29-31-03 MEASURED THE WIRES BETWEEN G RSVR HYD QTY XMTR(25GQ), FWC(1WW2) AND SDAC(1WV), CHECKED NORMAL 10. PER AMM 12-12-29-00 REPLENISHED THE GREEN HYD SYS TO THE RECORD QTY 6.3GALLONS NOTE: COMPLIED WITH WORK CARD 3233000-00-31. TITLE: LANDING GEAR FREE FALL CABLE TENSION - FNC. PERFORMED FREE FALL EXTENSION TEST. TEST RESULT: NORMAL