What was found
MAIN CABIN FLOOR BEAM UNDER L1 DOOR PAN ALONG FULL LENGTH HAS SURFACE CORROSION IN SEVERAL SPOTS UNDER FLOOR PANEL AREA 221MBF. REMOVED AND REPLACED INTERCOSTAL IAW B757 DWG 141N8322 REV K