As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PASSING 8000 FEET, GOT R HYD QTY LOW WHICH TURNED INTO R HYD SYS PRESS. CONSULTED QRH, FOLLOWED PROCEDURE, DECLARED EMERGENCY AND LANDED SAFELY. ***EMERGENCY DECLARED*** INSTALLED FILTER MODULE REF AMM 29-11-17-4. SERVICED RIGHT HYD SYSTEM REF AMM 12-12-01-3. LEAK CHECKED FILTER MODULE AND THEN RAN RIGHT ENG FOR FIVE MINUTES REF JRH CHAP 5.. NO LEAKS WERE NOTED. OK FOR SERVICE.