What was found
MAIN CABIN - FLOOR PANEL IS SATURATED WITH HYDRAULIC FLUID AT STA 560 TO STA680 LBL 0 TO LBL 24. REMOVED AND REPLACED FLOOR PANEL AT STA 560-680 LBL 0 - LBL 24 IAW B757 AMM 53-01-01-4 AND FEDEX DWG SRZ-25-005 REV R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN - FLOOR PANEL IS SATURATED WITH HYDRAULIC FLUID AT STA 560 TO STA680 LBL 0 TO LBL 24. REMOVED AND REPLACED FLOOR PANEL AT STA 560-680 LBL 0 - LBL 24 IAW B757 AMM 53-01-01-4 AND FEDEX DWG SRZ-25-005 REV R.