What was found
LH OB FLAP LOWER SURFACE FROM IB TO OB 15.5 INCH CROSS TE TO LE 4 INCH FOUND ONE DENT. EVALUATED LH OB FLAP LOWER SURFACE FROM IB TO OB 15.5 INCH CROSS TE TO LE 4 INCH ONE DENT DAMAGE SIZE L X W=4"X2" WITH DISBOND WITHIN REPAIR LIMIT AS PER B777 SRM 57-53-01- 1A ALLOWABLE DAMAGE 2, REV44.0. REPAIRED THE DENT AS PER B777 SRM 57-53-01-2R-2 AND SRM 51-70-04-2R-1 AND SRM51-70-04-2R PARA 5N REV 44.0 AND EA G-5750-TO375717 P1, TITLE: WING-FLIGHT SURFACES-LH OUTBD FLAP TE WEDGE DENT WITH DISBOND AT OTEF STA 43-SRM REPAIR-RSC TRACKING.DETAIL PLS REFER TO WRI: 57503216. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.