What was found
LH WING OB FLAP LWR SURFACE FROM OB TO IB 233 INCHES CROSS TE TO LE 11 INCHES FOUND ONE DENT. EVALUATED LH WING OB FLAP LWR SURFACE FROM OB TO IB 233 INCHES CROSS TE TO LE 11 INCHES ONE DENT WITH DISBOND DAMAGE SIZE LXW=2.0"X1.0" OUT OF ALLOWABLE LIMIT AS PER B777 SRM 57-53-01-1A ALLOWABLE DAMAGE 2 REV 45.0.REPAIRED THE DAMAGE AS PER B777 SRM 57-53-01-2R REPAIR 2 ,SRM 51-70-04-2R-1 REPAIR 1 ,SRM 51-70-04-2R REPAIR GENERAL REV 45.0 AND EA G-5750-T0377872 P1 , REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.