What was found
POST-FLT INSPECTION, FOUND L1 DOOR HOLD-OPEN LOCK BROKEN. LINE MEL 09JUL24 07:07 MEM RELEASED FOR SERVICE PER MEL : 52-11-01-A CATEGORY : B MEL 52-11-01-A: L1 DOOR INOP. L1 DOOR HOLD-OPEN LOCK FOUND BROKEN. REMOVED BROKEN SPLIT LOCK PIECES AND PLACED IN THE COCKPIT. DOOR PLACED ON MEL. AIRCRAFT OKAY TO CONTINUE. AMM: 52-11-08-8 REMOVED AND REPLACED L1 DOR HOLD OPEN LOCK PER THE ABOVE REF. OPS CHECK GOOD. OK FOR CONT'D SVC.