What was found
R REV ISLN VAL STATUS MESSAGE DURING CLIMB. REVERSER SECURED IN FORWARD THRUST POSITION." MEL: 78-31-01-01 R/H T/R DEACTIVATED PER MEL PROCEDURE. REVERSED MEL DESACTIVATION PROCEDURE FOR TROUBLESHOOTING PERFORMED CLEANING OF THE THRUST REVERSER ISOLATION VALVE PRESSURE SWITCH PLUG PERFORMED USUAL TEST OF RIGHT THRUST REVERSER TEST OK COULD NOT DUCPLICATE FAULT NO FAULT FOUND, PERFORMED T/S PER FIM 78_34_00_815_806_R05 FOUND ON LEFT SLEEVE PROXIMITY SENSOR CLERANCE OUT OF TOLERANCE , PERFORMED ADJUSTMENT ON SENSOR S10105 PER MM 78-30-00-5-4 , AND PERFORMED BITE TEST ON PSEU PER FIM 32_09_03_815_804 WITH NO FAULT FOUND. PERFORMED SEVERAL TEST ON RIGHT THRUST REVERSER PER MM WITH NO FAULT FOUND .