What was found
EMERGENCY EXIT LIGHTS ARE UNARMED WHEN EMERGENCY EXIT LIGHT SWITCH IS CLOSED. FOUND SWITCH GUARD SPRING LOAD OUTSIDE OF THE SWITCH, REPOSITIONED THE SPRING, PERFORMED EMERGENCY LIGHTS OPERATIONAL IAW AMM 33-51-00-5 TEST OK
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT LIGHTS ARE UNARMED WHEN EMERGENCY EXIT LIGHT SWITCH IS CLOSED. FOUND SWITCH GUARD SPRING LOAD OUTSIDE OF THE SWITCH, REPOSITIONED THE SPRING, PERFORMED EMERGENCY LIGHTS OPERATIONAL IAW AMM 33-51-00-5 TEST OK