Service difficulty report · Electrical Sys · Boeing 777FS2

Difficulty date
December 27, 2024
Submitted
December 27, 2024
Operation
Air carrier
Aircraft
N889FD
Make and model
Boeing 777FS2
Aircraft serial
41067
Aircraft time
46,291 hours, 7,681 cycles
Part
Electrical Sys
Condition
Malfunctioned
Stage of operation
IN
How discovered
O
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING COCKPIT SETUP. ACFT POWER SURGED & POPPED OFF. ALL SCREENS WENT BLACK. POWER CAME BACK ON A FEW SECS LATER. POWER THEN DROPPED OFF AGAIN & CAME BACK. THERE WAS THEN A STRONG ODOR OF ELECTRICAL SMOKE IN COCKPIT. THERE WAS ALSO A POPPED INTERPHONE CIRCUIT BREAKER. RAN APU & BOTH ENGINES. PERFORMED GENERATOR DRIVE SYS OPS TEST, PEFORMED AC GENERATION AND BUSS CONTROL TEST, PERFORMED POWER & REGULATION OPS TEST. ALL TESTS PASSED. ALL GENERATORS POWERED APPRORIATE BUSSES DURING TESTS. AFTER ALL TESTS PERFORMED CHECKED CIRCUIT BREAKERS IN COCKPIT & MEC TO ENSURE NO NEW CIRCUIT BREAKERS HAD OPENED DURING APU & ENG RUNS. NO NEW CIRCUIT BREAKERS FOUND OPEN.