What was found
VERY LARGE DENT IN THE FUSELAGE DISCOVERED BELOW AFT ABK DOOR. FABRICATED & DRILLED REPLACMENT STRINGER SECTION FROM FULL 37L STRINGER SECTION IAW SRM 53-00-03-2R. APPLIED WHITE TOP COAT TO ALL REPAIR PARTS IAW AMM 51-21-10-7. FABRICATED, LOCATED, DRILLED. TRIMMED, & ALODINED -1, -4, AND -5 DOUBLERS AND -2, -3, AND -6 FILLERS IAW SRM 53-60-01-2R AND EA H-5330-T383200 P2 AMM: 51-21-10-07 ALL PARTS HAVE BEEN PRIMED AND PAINT APPLIED. REF AMM 51-21-10-07. COMPLIED WITH STRINGER 37L REPAIR IAW EA H-5330-T0383200 P2 & SRM 53-00-03-2R-2 AND COMPLIED WITH SKIN REPAIR IAW EA H-5330-T0383200 P2 & 53-60-01-2R-1. FINAL STEP WAS TO APPLY TOPCOAT TO THE REPAIR AREA. RESTORED TOPCOAT PER AMM 51-21-10-7.