What was found
UPON CONFIGURING FROM FLAPS 20 TO FLAPS 25, LE SLAT DISAGREE MESSAGE AND CAUTION LIGHT ILLUMINATED. RAN QRH, LANDED FLAPS 20. EMERGENCY DECLARED. AMM 27-58-00-5 ALL WORK PERFORMED IAW TSI 27-50/4817 AND ABOVE REF, A/C OPS CHECKS NORMALLY WITH NO FAULTS AT THIS TIME . A/C OK TO CONTINUE.