What was found
RH LOBE INTERIOR BETWEEN BS 1720 AND STR 17 HAS CREASE BEAM WITH CRACK 2 INCH APROX. ACCOMPLISHED REPAIR ON ADDITIONAL DAMAGE FOUND: CRACK IN THE HOLE AT AFT PRESSURE BULKHEAD STA 1720 PER FEDEX E.A.#: F-5310-T0385818 P1 WITH TITLE: FUSELAGE - MAINFRAME - BS 1720 AFT PRESSURE BULKHEAD - HOLE FOUND WITH CRACK INDICATION AT S-17R AND REPAIR ON CREASE BEAM OUTER CHORD WITH CRACK STA 1713, STR-17R WAS ACCOMPLISHED PER FEDEX E.A.#: F-5310-T0385818 P1 WITH TITLE: FUSELAGE - MAINFRAME - R4 DOOR LOWER SILL / CREASE BEAM - OUTER CHORD ORIZONTAL FLANGE CRACK AT STA 1713, S-17R