What was found
EXISTING REPAIR ON FUSELAGE SKIN BETWEEN FR54.2-FR54.3,STGR46L-STGR49L REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON FUSELAGE SKIN BETWEEN FR54.2-FR54.3,STGR46L-STGR49L. NO RECORD FOUND. REMOVED THE EXISTING REPAIR AND PERFORMED THE NEW REPAIR IAW SRM 53-10-12 FIG.209, EO 6-5100-7-5000, D7, PT1 WAS COMPLETED. CLASSIFIED AS MAJOR IAW GMM 6-2-100. THE FIRST INSPECTION THRESHOLD, 42500FC AFTER REPAIR EMBODIMENT.THE REPETITIVE INSPECTION INTERVAL:TBD.THE INSPECTION METHOD, EDDY CURRENT/ULTRASONIC IAW SRI 53-10- 12-2-003-00. MAJOR REPAIR IAW FEDEX GMM6-2-100.