What was found
DURING INSPECTION FOUND EVIDENCE OF STRIKE AT BS 368, STRINGER 5R, DOOR STA 108 3/4" INBD OF STR 5R, REPAIRED SKIN USING COMPLING WITH EA.H-5330-T0388341P1 (PART 1 OF THIS EA PROVIDES INSTRUCTIONS TO ACCOMPLISH SRM 53-00-01-2R, REPAIR 29, WITH CLARIFICATION ON DOUBLER THICKNESS & APPLICABLE REPAIR FASTENERS DUE TO THE CHEM-MILLED AREAS USING APPROVED DATA, MAJOR REPAIR.