What was found
(FOTR) BWS 910, FRAME LT SIDE OF FUSELAGE HAS A DOUBLE DRILL AT FLOOR LEVEL. CUT OUT DAMAGED AREA DIM .700" X .500" ON FRAME STA 910 LT FLOOR LEVEL IAW SRM 51-40-3, FIG 1. FAB DOUBLER FROM 7075-0 .80" PO 9009327 IAW SRM 51-40-3, FIG 1. TREATED AND PRIMED PART IAW SRM 51-10-2. INSTALLED REPAIR DOUBLER IAW SRM 51-40-3, FIG 1 DTE REQUIRED WITHIN 12 MONTHS.