As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN OVERWING FLOORBEAM T-CORD CRACKED AT RADIUS BS 760 45.5. REMOVED DAMAGED T-CORD FROM STA 760-870, RBL 45 IAW SRM 51-30-2. FABRICATED NEW T-CORD FROM BAC1506-1108 7075-T6 PO 2019835 DIM 109.6250" X 3.6250" IAW SRM 53-10-2, FIG 7. INSTALLED T-CORD IAW SRM 51-30-2 AT MAIN CABIN OVERWING FLOORBEAM T-CORD BS 760-870 RBL 45.