What was found
BS 950F, FRAME HAS 2 RIVETS W/NO E.D. IN WINDOW BELT AREA. CUT OUT DAMAGE AREA 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2 EA PARTS MAT USED 7075-0 .071" PO 900163-801, REV A; LOCATED AND DRILLED IAW SRM 51-30-5, HEAT TREATED FROM 7075-0 TO 7075-T6 IAW FAS ENG REPORT NR 2-37153-801, REV A. TREATED AND PRIMED IAW SRM 51-10-2, INSTALLED REPAIR PARTS IAW SRM 51-30-2.