What was found
BS 910 FRAME HAS 2 FASTENERS W/NO E.D. AT GILLINER SUPPORT IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGE AREA DIM 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2EA PARTS MAT USED 7075-0 .071" PO 90016396. DIM 14.5" X 3", 14.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATED PARTS FROM 7075-0 TO 7075-T6 IAW FAS ENG REPORT 2-37153-801 REV A LOCATED AND DRILLED 2 EA REPAIR FRAME IAW SRM 51-30-5 TREATED AND PRIMED IAW SRM 51-10-2. INSTALLED REPAIR FRAME IAW SRM 51-30-2.