As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STA 720F FRAME HAS FASTENERS W/NO E.D. IN WINDOW AREA. CUT OUT DAMAGE AREA DIM. 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR MAT, USED 7075-0 .071" PO NR 90016396. DIM 13.5" X 3" AND 13.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATED PARTS FROM 7075-0 TO 7075-T6 IAW FAS ENG. REPORT NR 2-37153-801 REV A. LOCATED AND DRILLED IAW SRM 51-30-5. TREATED AND PRIMED IAW SRM 51-10-2. INSTALLED FRAME REPAIR IAW SRM 51-30-2.