What was found
(FOTR) ON THE LT INBD MID FLAP SKIN IS PUNCTURED NEAR INBD END ON LWR SURFACE WHERE AFT FLAP MATES WITH MID FLAP. REMOVED DAMAGED AREA CUT OUT SIZE 4.5" X 4.0" LT MID FLAP INBD AFT LOWER T/E SKIN, IAW SRM 51-10-1 AND 57-50-4. OBTAINED MAT FOR FILLER 2024-T3 .032", PO 90010222 AND DOUBLER 2024-T3 .040" PO 900729 FAB REPAIR FILLER AND DOUBLER IAW SRM 57-50-4 FILLER DIM. 4.8" X 3.78" DOUBLER 5.3750" X 5.2500" TREATED AND PRIMED PARTS IAW SRM 51-10-2 INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-30-2 AND 57-50-4.