What was found
BS 440, RBL 60 FRAME HAS DOUBLE DRILL AT FLOOR LEVEL. CUT DAMAGE AREA AT STA 440 RT FRAME DIM 1.2500" X 1" IAW SRM 51-40-3. FAB NEW REPAIR FRAME FROM 7075-0 .063" PO NR 9009913. DIM 10" X 4" LOCATED, DRILLED & HEAT TREATED TO T6 CONDITION IAW FAS ENG. REPORT 2-87153-801 REV A. INSTALLED, TREATED & PRIMED ALL IAW SRM 51-30-5, 51-30-6,51-30-2,51-10-2.