What was found
UPON REMOVAL OF INTERCOSTAL FOUND FUSELAGE SKIN TO BE CORRODED BETWEEN BS 700-720 STR 28R-27R. REMOVED 8" BODY FAIRINGS FROM 710 TO 720 LT AND RT IAW SRM 51-30-2. CUT DAMAGE AREA AND FOUND OUT OF LIMITS DIM 53" X 51" FROM STA 680 TO 720+14.5" IAW SRM 53-30-3, FIG 12. FAB SKIN FROM 2024-T3 .063" DIM 53" X 50.5" PO 20198112 & FAB SPLICE FROM 2024-T3 .071" DIM 50.5" X 6" PO 90010664 ALL IAW SRM 53-30-2, FIG 12. DETAIL XII, TREATED AND PRIMED ALL PARTS & AREAS FROM 680 TO 720+15" IAW SRM 51-10-2. NEW SKIN & SPLICE INSTALLED FROM 680 TO 720+14 IAW SRM 53-30-3, FIG 12, DETAIL XII. REINSTALLED 8 EA BODY FAIRINGS SUPPORT FROM STA 710 TO 720A LT & RT SRM 51-30-2.