As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BS 1148 AT STR 14R FRAME HAS 2EA DRILL STARTS UNDER GILLINER SUPPORT. CUT OUT DAMAGE AREA DIM. 1.3750" X 1" IAW SRM 51-40-3, FIG 1. FABRICATED ANGLE FROM 7075-0 .100" PO 824299 IAW SRM 51-40-3, FIG 1. HEAT TREATED TO 7075-T6 .100" TREATED AND PRIMED PART IAW SRM 51-10-2. INSTALLED REPAIR PART IAW SRM 51-40-3, FIG 3. DTE REQUIRED WITHIN 12 MONTHS.