What was found
NR 2 SLAT LWR SKIN CRACKED AT INBD TRACK TO SKIN ATTACH FASTENERS. CUT OUT DAMAGED AREA DIM 3.3" X 5.55" IAW SRM 57-50-3, FIG 1. FABRICATED REPAIR DOUBLER FROM 7075T6 .080 PO 90011142 DIM 6.75" X 7.4" AND FILLER FROM 7075T6 .080 PO90011142 DIM 5.55" X 3.3" IAW SRM 57-50-3, FIG 1 AND 57-50-2 FIG 2 AND 51-20-1, FIG 2. INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 57-50-3, FIG 1. FASI NR 12315.