What was found
PILOTS REPORTED AN ODOR OF SMOKE COMING FROM THE VENTS AFTER PARKING AT THE GATE. MAINTENANCE PLACED THE RECIRCULATION FAN ON MEL IAW 21-25-1 CATEGORY C. MAINTENANCE SUBSEQUENTLY REMOVED AND REPLACED THE LT RECIRCULATION FAN IAW MM 21-25. OPERATIONAL CHECK GOOD.