Service difficulty report · Circuit Breaker · Emb EMB120ER

Difficulty date
November 16, 2008
Submitted
November 26, 2008
Operation
Air carrier
Aircraft
N293UX
Make and model
Emb EMB120ER
Aircraft serial
120293
Aircraft time
24,986 hours, 26,738 cycles
Part
Circuit Breaker
Part number
MS2536180
Condition
Contaminated
Location
Zone 100
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENROUTE, PILOTS REPORTED AN EMERGENCY BUSS OFF LIGHT ILLUMINATED IN FLIGHT. EMERGENCY ACTIONS WERE TAKEN. MAINT WAS DISPATCHED TO THE ACFT AND SECURED A WIRE HARNESS IN THE OVERHEAD CIRCUIT BREAKER PANEL. MAINT CHECKED THE TORQUE OF THE RCCB AND FEED WIRING HARDWARE IN THE LT DC RELAY BOX AND PERFORMED FUNCTIONAL CHECKS OF THE AFFECTED SYS. OPS CHECKS WERE GOOD. THE ACFT WAS RAN, TAXIED, AND NO DEFECTS WERE NOTED. ALL IAW MM 24-51. AN OPS CHECK FLIGHT WAS PERFORMED AND THE OPS CHECK FLIGHT WAS SATISFACTORY. UPON ENTRY INTO A SCHEDULED MAINT CHECK MAINT REMOVED AND REPLACED THE EMERGENCY BUSS CIRCUIT BREAKER CB 0470 P/N MS25361-80 PRECAUTIONARY DUE TO EVIDENCE WHICH APPEARED TO BE A POSSIBLE COFFEE SPILL PREVIOUSLY IAW MM 24-52. ALL CHECKS WERE GOOD.

More about the Emb EMB-120ER