Service difficulty report · Circuit Breaker · Emb EMB120ER

Difficulty date
February 27, 2009
Submitted
February 28, 2009
Operation
Air carrier
Aircraft
N293UX
Make and model
Emb EMB120ER
Aircraft serial
120293
Aircraft time
25,589 hours, 27,337 cycles
Part
Circuit Breaker
Part number
M833830110
Condition
Fused
Location
Electrical Sys
Stage of operation
CR
How discovered
O
Nature of condition
S
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DIVERSION - FLIGHT 5118 - EN ROUTE FROM "ISN" PILOTS REPORTED, LOST EMERGENCY DC BUS 2 WHILE INFLIGHT. PERFORMED AN ELECTRICAL GEAR FREEFALL. MAINTENANCE REMOVED AND REPLACED CIRCUIT BREAKER CB0048 WHICH WAS FOUND FUSED (STUCK CLOSED) WITH SERVICEABLE RCCB AND TESTED GOOD IAW EMB WIRING MANUAL 20-00-06. MAINTENANCE PERFORMED A LANDING GEAR TEST IAW EMB-120 32-30-00. OPERATIONAL TEST WAS GOOD. ADDITIONALLY THE AUX DROP PUMP CIRCUIT BREAKER HAD POPPED AND THE PILOTS LEFT IT OUT. MAINTENANCE REMOVED AND REPLACED THE RIGHT AUX PUMP IAW EMB-120 MM 61-23-11. OPERATIONAL AND LEAK CHECKS WERE GOOD. AN OPERATIONAL CHECK FLIGHT WAS REQUESTED/PERFORMED AND WAS FOUND SATISFACTORY.

More about the Emb EMB-120ER