What was found
MAJOR REPAIR - DURING A SCHEDULED ROUTINE INSPECTION FOUND A CRACK IN THE CARGO DOOR FRAME, FWD SIDE, FS 456, BETWEEN STRINGER 3L AND 4L, .7" IN LENGTH. MX REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 11-1900-53-056. MATERIALS UTILIZED ARE INCLUDED IN THE EO.