What was found
AFTER SWINGING GEAR 11 TIMES, THE INTRANSIT LIGHT DID NOT ILLUMINATE, DID NOT HEAR HYD PUMP. MX REPLACED THE SELECTOR VALVE IAW AMM 32-30-03, OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER SWINGING GEAR 11 TIMES, THE INTRANSIT LIGHT DID NOT ILLUMINATE, DID NOT HEAR HYD PUMP. MX REPLACED THE SELECTOR VALVE IAW AMM 32-30-03, OPS CHECKED GOOD.