What was found
DURING A SCHEDULED ROUTINE INSPECTION, FOUND 2 CRACKS ON MAIN SPAR WEB AT HSS 3.0L AND 3.0R, 1 INCH IN LENGTH. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 12-1900-55-010. MATERIALS UTILIZED ARE INCLUDED IN THE EO. MAJOR REPAIR