What was found
DURING A SCHEDULED ROUTINE INSPECTION, FOUND A CRACK IN THE FRAME AT FS 150 AND STRINGER 9AL, AT NUTPLATE FOR A/S DOOR STRUT LWR MOUNT, .75" IN LENGTH. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 12-1900-53-028. MAJOR REPAIR.