What was found
DURING A SCHEDULED ROUTINE INSPECTION FOUND A CRACK IN THE LT SPAR CAP ON VERTICAL STAB AT HORIZONTAL STAB ATTACHMENT FITTING AT 2ND FASTENER FROM TOP, VSS 84.10 AT 20 PERCENT CHORD, .875" IN LENGTH. REPAIRED IAW FR-CO-02526, REV 1, STEP 1. MAJOR REPAIR.