As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A SCHEDULED INSPECTION FOUND A LIGHTNING STRIKE ON THE OTBD TE LT ELEVATOR JUST OTBD OF THE MOST OTBD STATIC WICK. SKIN HAS .5 INCH X .25 INCH DAMAGE STARTING INBD OF THE FIBERGLASS END CAP & TRAVELING OUTWARD UNDER THE END CAP, DAMAGING THE END CAP. THE END CAP ALSO HAS AN EXIT HOLE 0.125 INCH IN DIAMETER. REPAIRED THE AFFECTED AREA & PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 14-1900-27-003. MATERIALS UTILIZED ARE INCLUDED IN THE ENGINEERING ORDER.