What was found
FTW - OXYGEN MASK DROP TEST FAILED. T/S SYSTEM FOUND WIRES GOING TO CONNECTOR P1-1209 CHAFING. REPAIRED WIRES IAW OPS 20-10-01 SYSTEM TAKEOFF GROUND TEST GOOD IAW MD80 MM 35-20-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - OXYGEN MASK DROP TEST FAILED. T/S SYSTEM FOUND WIRES GOING TO CONNECTOR P1-1209 CHAFING. REPAIRED WIRES IAW OPS 20-10-01 SYSTEM TAKEOFF GROUND TEST GOOD IAW MD80 MM 35-20-00. (M)