What was found
ACY - FLT 1265 - AUTO SLAT FAIL LIGHT ILLUMINATED DURING FLAP EXTEND FOR T/O TESTED STALL WARN BOTH 1 AND 2 TEST WAS SATISFACTORY. RETURNED TO GATE FOR MAINTENANCE. TESTED AND CLEANED CONNECTORS ON GROUND PROXIMITY UNIT-CYCLED NUMEROUS TIMES, OPS CHECKS OK PER MM 32-60-04 AND 27-80-00. (M)