What was found
FTW - FOUND STRINGER 30 CORRODED FS 617 TO 610, FS 617-636, 636-655, 674-655. FOUND TO BE OUT OF LIMITS. REMOVED LONGERON REPAIR STATION. FABRICATED LONGERON SPLICES AND REPAIR STATION. INSTALLED LONGERON 30 AND SPLICES REPAIR. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND STRINGER 30 CORRODED FS 617 TO 610, FS 617-636, 636-655, 674-655. FOUND TO BE OUT OF LIMITS. REMOVED LONGERON REPAIR STATION. FABRICATED LONGERON SPLICES AND REPAIR STATION. INSTALLED LONGERON 30 AND SPLICES REPAIR. (M)