Service difficulty report · Computer · Airbus A319132

Difficulty date
September 16, 2013
Submitted
September 17, 2013
Operation
Air carrier
Aircraft
N533NK
Make and model
Airbus A319132
Aircraft serial
3393
Aircraft time
22,313 hours, 10,732 cycles
Part
Computer
Part number
41600318003
Condition
Failed
Location
Window Heat
Stage of operation
CL
How discovered
O
Nature of condition
W, B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SULFURIC AND BURNING PLASTIC ODOR DURING CLIMB, INCREASING WITH ALTITUDE. HAZE IN COCKPIT AND CABIN. RETRIEVED PFR. NO FAULT MESSAGE RECORDED. PERFORMED AEVC TEST IAW AMM 21-26-00-710-001-A. TEST OK. PERFORMED TEST OF PACK TEMP CONTROL SYS IAW AMM 21-61-00-710-001-A. TEST OK. PERFORMED TEST OF BOTH BCL'S AMM 24-38-00-710-001-A. APPLIED TSM 24-00-00-810-823-A ELECTRICAL BURING ODOR FOUND IN THE CABIN, COCKPIT. FOUND APU OVERSERVICED, CORRECTED OIL LEVEL AMM 12-13-49-612-001-A. PERFORMED IDLE ENG RUN AT THE GATE IAW AMM 71-00-00-710-043-A. STARTED NORMAL DURING PERFORMED HIGH POWER ASSURANCE TEST IAW AMM 71-00-00-710-013-C. DURING RUN PERFORMED OPS TEST OF THE BLEED SYSTEM IAW AMM 36-11-00-710-003-A. ALL PARAMETERS NORMAL. DURING THE ENGINES RUN RECIEVED ECAM WARNING ANTI ICE RT WINDOW & HAZE THROUGH OUT CABIN. DEACTIVATED WHC 2 FOR FAULT CONFIRMATION.PERFORMED HIGH POWER ASSURANCE TEST IAW AMM 71-00-00-710-013-C. DURING RUN PERFORMED OPS TEST OF THE BLEED SYSTEM IAW AMM 36-11-00-710-003-A. ALL PARAMETERS NORMAL. INSPECTED AVIONICS FILTERS FOR CONDITION. REMOVED AND REPLACED FILTERS IAW AMM 21-26-43-000-006-A & AMM 21-26-43-400-006-A. REMOVED & REPLACED WHC 2 IAW AMM 30-42-34-000-001-A & AMM 30-42-34-400-001-A.PERFORMED TEST IAW AMM 30-42-00-710-001.PERFORMED ENGINES RUN AT IDLE IAW AMM 71-00-00-710-043-A. NO DEFECTS NOTED AT THIS TIME.

More about the Airbus A319-132