As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R2 DOOR ACCUMULATOR PRESSURE LOW. R & R THE R2 DAMPNER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-13-14-400-001-B. SERVICED THE DOOR DAMPNER AND EMERGENCY OPERATION CYLINDER TO LIMITS IAW AMM 52-10-00-614-001-A. OPS AND LEAK CHECK GOOD, ACFT OK TO CONTINUE.