What was found
DURING DESCENT, RECEIVED A VENT EXTRACT FAULT. PERFORMED ECAM, DONNED OXYGEN MASKS FOR A BURNING PLASTIC ODOR. FOUND EXTRACT FAN MAKING NOISE AND HOT TO TOUCH. R & R THE EXTRACT FAN IAW AMM 21-26-51, OPS CHECKED OK IAW AMM 21-26-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING DESCENT, RECEIVED A VENT EXTRACT FAULT. PERFORMED ECAM, DONNED OXYGEN MASKS FOR A BURNING PLASTIC ODOR. FOUND EXTRACT FAN MAKING NOISE AND HOT TO TOUCH. R & R THE EXTRACT FAN IAW AMM 21-26-51, OPS CHECKED OK IAW AMM 21-26-00.