What was found
DIRTY SOCK SMELL DURING DESCENT AND APP PROCEDUE APPLIED FOR PACK 1 ODER WENT AWAY ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-UPON INSP. FOUND #1 ENG DEOIL SEAL LEAKING.R/R SEAL ASSY. IAW AMM 72-60-31.OPS CHK,LEAK CHK GOOD.(REACTIVATED PACK #1) PERFORMED PACK BURN OUT IAW AMM 21-61-00.OPS CHK GOOD,NO DEFECTS NOTED AT THIS TIME.PLACARD REMOVED,MOC NOTIFIED,DMI 2838507-1 CLEARED.